閉鎖生態系実験施設用圧力制御システムの動作解析
-
中野 晋
,
内田 剛
,
石ヶ森 勲
,
菅原 敏
,
新田 慶治
… It is necessary to develop a small positive pressure control system for the closed ecology experiment facilities because of the needs to prevent contamination from the atmosphere and to protect against over differential pressure loading. … In the present study, a numerical analysis method was developed to calculate the quantity of state of the closed module which is fitted with rubber buffers for the small positive pressure control system. …
日本機械学會論文集. B編 64(617), 107-114, 1998-01-25
CiNii PDF - オープンアクセス