1108 Scale effect for a diffuser type valve-less micro-pump(2)
[in Japanese]
-
MORIYAMA Shun
,
TANAKA Seiichi
,
TSUKAMOTO Hiroshi
,
MIYAZAKI Koji
… The effect of channel size on the characteristics of valve-less micro-pump with diffuser shaped element was investigated. … The micro-pump consists of a diffuser shaped micro-channel and a chamber with a diaphragm, the vibration of which produces on oscillating flow. … The pump performance of the diffuser type valve-less micro-pump with the cross sectional dimensions of 250μm×250μm was compared with previous data on 1mm×1mm micro-pump. …
Fluids engineering conference ... 2007, "1108-1"-"1108-4", 2007-11-17
CiNii Fulltext PDF - Subscription