X線透過型移相子の放射光での利用

  • 平野 馨一
    高エネルギー物理学研究所・放射光実験施設・測定器研究系

書誌事項

タイトル別名
  • Application of X-ray Transmission Phase Plates to Synchrotron Radiation.
  • Xセン トウカガタ イソウシ ノ ホウシャコウ デ ノ リヨウ

この論文をさがす

抄録

X-ray transmission phase palates are described based on the dynamical theory of X-ray diffraction. Polarization-tunable X-ray optics using transmission phase plates for synchrotron radiation (SR) were proposed and were used to transform horizontal polarization of SR to circular or vertical polarization at a bending-magnet beamline, BL-15C at the Photon Factory (PF) . Combination of x-ray transmission phase plates and X-ray polarization analyzer enabled us to determine full state of polarization in the X-ray spectral region. With this polarization analysis method, polarizations of X-rays from an elliptical multipole wiggler installed on BL-28 at the PF were successfully estimated.

収録刊行物

被引用文献 (1)*注記

もっと見る

参考文献 (24)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ