書誌事項
- タイトル別名
-
- Effect of Fouling on Nucleate Boiling
- カク フットウ トクセイ エ ノ ヨゴレ ノ エイキョウ
この論文をさがす
抄録
The more vigorous bubbling was observed on a silicon-coated copper surface compared to that on a clean mirror-finished surface at a same heat flux. The enhancement of the bubbling was associated with the fact that the non-wetting porous structure in the silicon coating provided the sufficient number of active sites for bubbling nucleation. As the result, the nucleate heat transfer coefficient on the silicon-coated surface was higher than that on the clean mirror-finished surface. On the other hand, the nucleate boiling heat transfer coefficient on the fouling surface was approximately the same as that on the mirror-finished surface. The fouling scale was also the porous material but the wettability was high.
収録刊行物
-
- 日本舶用機関学会誌
-
日本舶用機関学会誌 32 (1), 50-55, 1997
公益社団法人 日本マリンエンジニアリング学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390001205161565312
-
- NII論文ID
- 10002041367
-
- NII書誌ID
- AN00196373
-
- ISSN
- 18844758
- 03883051
-
- NDL書誌ID
- 4117569
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可