Gas Holdup in Bubble Column with Draft Tube for Gas Dispersion into Annulus

この論文にアクセスする

この論文をさがす

著者

抄録

The effect of kind of gas sparger, outer diameter <I>D</I><SUB>o</SUB> and length <I>L</I><SUB>d</SUB> of draft tube, lower clearance, superficial gas velocity and clear liquid height <I>H</I><SUB>L</SUB> on gas holdup <I>ε</I><SUB>G</SUB> in a 0.16 m I.D. bubble column with a draft tube for gas dispersion into the annulus and for an air-water system was experimentally studied.<BR><I>ε</I><SUB>G</SUB> depended on the kind of gas sparger in the range of <I>φ</I> ≤ 0.713, but hardly depends on them at <I>φ</I> = 0.875. <I>φ</I> is the ratio of (<I>D</I><SUB>o</SUB>/<I>D</I><SUB>T</SUB>) and <I>D</I><SUB>T</SUB> is the inner diameter of the bubble column.<BR>At a given <I>H</I><SUB>L</SUB> and in the range of <I>φ</I> ≤ 0.713, <I>ε</I><SUB>G</SUB> hardly depends on <I>φ</I> and <I>L</I><SUB>d</SUB>. But <I>ε</I><SUB>G</SUB> decreases clearly with increasing <I>L</I><SUB>d</SUB> at <I>φ</I> = 0.875.<BR><I>ε</I><SUB>G</SUB> decreases with increasing <I>H</I><SUB>L</SUB>. The effect of <I>H</I><SUB>L</SUB> is well expressed by the modified three-region model.<BR>The experimental data for <I>ε</I><SUB>G</SUB> is correlated.

収録刊行物

  • Journal of chemical engineering of Japan  

    Journal of chemical engineering of Japan 31(2), 289-294, 1998-04 

    The Society of Chemical Engineers, Japan

参考文献:  7件

参考文献を見るにはログインが必要です。ユーザIDをお持ちでない方は新規登録してください。

各種コード

  • NII論文ID(NAID)
    10002065356
  • NII書誌ID(NCID)
    AA00709658
  • 本文言語コード
    ENG
  • 資料種別
    SHO
  • ISSN
    00219592
  • NDL 記事登録ID
    4483643
  • NDL 雑誌分類
    ZP1(科学技術--化学・化学工業)
  • NDL 請求記号
    Z53-R395
  • データ提供元
    CJP書誌  NDL  J-STAGE 