Optimum Feed Point for Isotope Separating Thermal Diffusion Column

この論文にアクセスする

この論文をさがす

著者

    • YAMAMOTO Ichiro
    • Department of Nuclear Engineering, Faculty of Engineering, Nagoya University
    • MAKINO Hitoshi
    • Department of Nuclear Engineering, Faculty of Engineering, Nagoya University
    • KANAGAWA Akira
    • Department of Nuclear Engineering, Faculty of Engineering, Nagoya University

抄録

A relation satisfied by an optimum feed point (axial height lopt:a dimensionless height from the bottom), which maximize separation factor (and, then, separative power), was derived based on an approximate column constants in terms of operating condition such as temperature difference between hot and cold walls ΔT, feed flow rate F, pressure P, and cut θ as well as geometrical condition of thermal diffusion column for isotope separation. The value of lopt is obtained through Newton iterative solution of this relation. As for an ordinary cold-wall (Tc=288K) thermal diffusion column separating H2-HT (Tracer level: 7.3×10-10) mixture, the authors got lopt=-0.2 for operating conditions that ΔT=1, 000K, F=5×10-5m3 (i.e. 50cm3)/min (at 0.1MPa, 288K), and θ=0.5. The optimum point obtained through a rigorous two-dimensional analysis by changing parametrically the feed point was lopt=-0.17, and the optimum point can, therefore, be predicted well even by the present simple model. Moreover, the optimum feed position exists closely near the point where the radially averaged HT-concentration coincides with the feed mole fraction.

収録刊行物

  • Journal of nuclear science and technology  

    Journal of nuclear science and technology 32(3), 200-205, 1995-03-25 

    Atomic Energy Society of Japan

参考文献:  19件

参考文献を見るにはログインが必要です。ユーザIDをお持ちでない方は新規登録してください。

各種コード

  • NII論文ID(NAID)
    10002072174
  • NII書誌ID(NCID)
    AA00703720
  • 本文言語コード
    ENG
  • 資料種別
    ART
  • ISSN
    00223131
  • データ提供元
    CJP書誌  J-STAGE 
ページトップへ