Criticality Safety Calculations of 'Poison Tube Tank' Compared with Annular Tanks for Storing Fissile Solutions.
-
- GOPALAKRISHNAN C.R.
- Safety Research and Health Physics Group, Indira Gandhi Centre for Atomic Research
-
- JOSEPH GEORGE
- Safety Research and Health Physics Group, Indira Gandhi Centre for Atomic Research
この論文をさがす
抄録
A comparative study of the shielded area space required for storing fissile solution by the conventional annular tank and by poison tube tank is made. Poison tube tank is similar to commercial heat exchanger. The neutron poisons studied are gadolinium oxide and borax. Variation of multiplication factor for an array of annular tanks containing uranium nitrate or plutonium nitrate solutions are presented for annular widths of 10, 7.5 and 5cm. It is concluded that for the given concentration, 5cm annular width tanks are safe at a pitch distance of 120 and 90cm for uranium and plutonium solutions respectively. Using these, as reference values, it is found that the shielded area saving for the poison tube tank is a factor of 12 and 8 for the given concentration of uranium and plutonium solutions respectively.
収録刊行物
-
- Journal of Nuclear Science and Technology(日本原子力学会英文論文誌)
-
Journal of Nuclear Science and Technology(日本原子力学会英文論文誌) 32 (4), 333-338, 1995
一般社団法人 日本原子力学会
- Tweet
キーワード
詳細情報 詳細情報について
-
- CRID
- 1390001204095537536
-
- NII論文ID
- 10002072406
-
- NII書誌ID
- AA00703720
-
- COI
- 1:CAS:528:DyaK2MXltFakurw%3D
-
- ISSN
- 18811248
- 00223131
-
- 本文言語コード
- en
-
- データソース種別
-
- JaLC
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可