Natural Convection Heat Transfer in the Horizontal Dry Storage System for the LWR Spent Fuel Assemblies

この論文にアクセスする

この論文をさがす

著者

抄録

A heat transfer and flow visualization experiment was conducted with a one-fifth scale model simulatinga dry shielded canister (DSC) with 24 PWR spent fuel assemblies in order to elucidate the heat transfer characteristics and the velocity distribution for natural convection inside a DSC filled with air or water at atmospheric pressure. It was found that the average heat transfer coefficients were proportional to the onefourth power of the Rayleigh number despite the complicated geometry inside the DSC. Flow patterns inside the DSC were visualized clearly through a digital image processing system. The velocity distributions inside the DSC were obtained quantitatively from the Particle Tracking Velocimetry. In comparison with the results of a two-dimentional thermal hydraulic analysis, computed flow patterns were similar to the experimental results and the computational temperature distributions on the sleeve surfaces agreed well with the experiments within 8%, except at the top point of the center gap. It was also found that the difference in the heat transfer coefficient was within 25% for air as the working fluid, while a satisfactory agreement was not obtained when water was the working fluid.

収録刊行物

  • Journal of nuclear science and technology  

    Journal of nuclear science and technology 33(11), p.821-828, 1996-11-25 

    Atomic Energy Society of Japan

参考文献:  16件

参考文献を見るにはログインが必要です。ユーザIDをお持ちでない方は新規登録してください。

被引用文献:  1件

被引用文献を見るにはログインが必要です。ユーザIDをお持ちでない方は新規登録してください。

各種コード

  • NII論文ID(NAID)
    10002075736
  • NII書誌ID(NCID)
    AA00703720
  • 本文言語コード
    ENG
  • 資料種別
    ART
  • ISSN
    00223131
  • NDL 記事登録ID
    4079950
  • NDL 雑誌分類
    ZM35(科学技術--物理学)
  • NDL 請求記号
    Z53-A460
  • データ提供元
    CJP書誌  CJP引用  NDL  J-STAGE 
ページトップへ