書誌事項
- タイトル別名
-
- Calculation of Monitoring Quantities for 239Pu Using ICRP Dosimetric Models for Internal Exposure.
- ICRP ノ ナイブ ヒバクセンリョウ ヒョウカ モデル ニ モトズク 239Pu ノ モニタリングリョウ ノ ケイサン
この論文をさがす
抄録
Plutonium (Pu) is one of the most important elements from the viewpoint of radiotoxicology and protection. The International Commission on Radiological Protection (ICRP) recently revised the respiratory tract model and biokinetic models for selected elements, including Pu. The monitoring quantities for inhaled 239Pu such as lung retention and daily excretion rate have been computed. The aerosols of 5μm Activity Median Aerodynamic Diameter (AMAD) and 1μm AMAD were treated by using these new models. The conversion coefficients from the monitoring quantities to the effective dose of 239Pu have been obtained. Besides the graphical representation, the computed monitoring quantities have been approximately represented by a summation of exponential functions. The present results provide useful data for the design of monitoring programs and for the interpretation of the monitoring results in occupational exposure.
収録刊行物
-
- 保健物理
-
保健物理 33 (4), 415-423, 1998
日本保健物理学会