Permeability Evaluation of Highly Permeable Rock Foundation by High Viscosity Fluid Test

  • YAMAGUCHI Yoshikazu
    Senior Research Engineer, Fill Dams Division, Dam Department, Public Works Research Institute, Ministry of Construction
  • SHIBUICHI Hideo
    Foundation Division, NITTOC Construction Co., LTD
  • MATSUMOTO Norihisa
    Director, Dam Department, Public Works Research Institute, Ministry of Construction

Bibliographic Information

Other Title
  • 高粘性流体試験による高透水性岩盤の透水性評価
  • コウ ネンセイ リュウタイ シケン ニ ヨル コウ トウスイセイ ガンバン ノ

Search this article

Abstract

To construct dams on highly permeable rock foundations rationally and economically, the accurate evaluation of permeability of dam foundations is required. When we perform Lugeon water-test(LWT), the most popular in-situ permeability test for dam foundations, in highly permeable rock foundations with high injection pressure, the water flow from an injection hole becomes the turbulent flow and the flow rate is not directly proportional to the injection pressure. Therefore, equivalent Lugeon value is dependent upon the injection pressure.<BR>On the other hand, when the water flow is laminar, the flow rate is directly proportional to the injection pressure and we have no trouble in calculating the Lugeon value. Besides, because the'hydraulic gradient of seepage in dam foundations is low and can be supposed to be almost laminar, laminar flow resistance law is necessary to estimate the amount of underseepage.<BR>In this paper, we have developed high viscosity fluid test (HVFT) to obtain the laminar flow resistance law of highly permeable rock foundations by injecting viscous fluid instead of water.

Journal

Citations (2)*help

See more

References(22)*help

See more

Details 詳細情報について

Report a problem

Back to top