Spectrophotometric Determination of Trace Iron after Collection and Elution as Its 8-Hydroxyquinoline-5-sulfonate Chelate on Protonated Chitin.

  • HOSHI Suwaru
    Department of Applied and Environmental Chemistry, Kitami Institute of Technology
  • TOMIZUKA Takashi
    Department of Applied and Environmental Chemistry, Kitami Institute of Technology
  • ENJO Chika
    Department of Applied and Environmental Chemistry, Kitami Institute of Technology
  • HAGA Yuko
    Department of Applied and Environmental Chemistry, Kitami Institute of Technology
  • UTO Masayuki
    Department of Functional Materials, Kitami Institute of Technology
  • AKATSUKA Kunihiko
    Department of Applied and Environmental Chemistry, Kitami Institute of Technology

この論文をさがす

抄録

A collection and elution method for anionic metal chelate on protonated chitin has been applied to the spectrophotometric determination of iron. Iron is collected as its anionic 8-hydroxyquinoline-5-sulfonate (8-HQ-5-S) chelate on a column of chitin in weak acidic medium. The iron(III)-8-HQ-5-S chelate collected on the chitin is effectively eluted with a small volume of 0.1mol dm-3 ammonia buffer solution (pH 9), and the absorbance of the eluent is measured at 571nm. Beer′s law is obeyed over the concentration range of 0.5 to 5μg of iron in 1cm3 of the eluent. Some metal ions and common inorganic anions do not interfere in concentration range of 100 to 1000 times that of iron, but the tolerance limit for Co, Ni and Cu is low due to the competitive reaction with 8-HQ-5-S. The present method can be applied to the determination of iron in tap and spring water samples.

収録刊行物

  • Analytical Sciences

    Analytical Sciences 11 (5), 729-732, 1995

    社団法人 日本分析化学会

被引用文献 (4)*注記

もっと見る

参考文献 (16)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ