Bubble Behaviour and Absorption Rate in Gas Injection through Rotary Lances.
-
- Díaz Manuela C.
- Graduate Student, Department of Materials Processing Engineering, Nagoya University
-
- Komarov Sergey V.
- Department of Materials Processing Engineering, Faculty of Engineering, Nagoya University
-
- Sano Masamichi
- Department of Materials Processing Engineering, Faculty of Engineering, Nagoya University
この論文をさがす
抄録
Bubble behaviour and absorption rate of gas injected into a liquid bath through rotary L-shaped lances were studied by cold models. A high-speed video recording system was used to measure the bubble diameter and the rising velocity. The absorption rate of injected CO2 gas in aqueous NaOH solution was measured by using a pH meter.<br> It is found that the lance rotation leads to a decrease in the bubble diameter and the rising velocity as compared with the stationary lance. The bubbles produced by a multi-hole lance are smaller than those produced by a single-hole lance. The reduction in the bubble rising velocity is connected with the decrease in the bubble diameter, distribution of bubbles over the liquid bath and distortion of the bubble rising path due to the lance rotation. <br>The gas absorption rate for the rotary lances is larger than that for the stationary lance. The effect of the rotation speed on volumetric mass transfer coefficient is larger at lower gas flow rate. The multi-hole lance can increase the volumetric mass transfer coefficient by about three times larger than the single-hole lance.<br>The results are discussed in terms of the bubble coalescence, mass transfer coefficient and total interfacial area between bubbles and liquid
収録刊行物
-
- ISIJ International
-
ISIJ International 37 (1), 1-8, 1997
一般社団法人 日本鉄鋼協会
- Tweet
キーワード
詳細情報 詳細情報について
-
- CRID
- 1390282681429334656
-
- NII論文ID
- 10002454602
-
- NII書誌ID
- AA10680712
-
- COI
- 1:CAS:528:DyaK2sXnsFOhsQ%3D%3D
-
- ISSN
- 13475460
- 09151559
-
- 本文言語コード
- en
-
- データソース種別
-
- JaLC
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可