温度逆変換法の研究と大気中銅アークプラズマへの応用 Study of A Temperature Inversion Method and Application to A Copper Arc Plasma in Air

この論文にアクセスする

この論文をさがす

著者

抄録

This paper describes a new inversion method to calculate back the internal information of the axially sym-metrical arc plasma such as the diameter in radial spectral intensity distribution, the peak spectral intensity, and the peak plasma temperature.<BR>The method only uses the integrated radiation intensities across the plasma column and along the central line of the plasma cross section. The temperature is given by use of the two line intensity ratio method.<BR>The inversion method was applied to a copper arc plasma in air.<BR>It was found out that the measured peak temperature of the arc plasma was good agreement with the theo-retical ones calculated back.

収録刊行物

  • 分光研究 = Journal of the spectroscopical research of Japan  

    分光研究 = Journal of the spectroscopical research of Japan 48(4), 154-159, 1999-08-15 

    The Spectroscopical Society of Japan

参考文献:  8件

参考文献を見るにはログインが必要です。ユーザIDをお持ちでない方は新規登録してください。

各種コード

  • NII論文ID(NAID)
    10002582898
  • NII書誌ID(NCID)
    AN00222531
  • 本文言語コード
    JPN
  • 資料種別
    ART
  • ISSN
    00387002
  • NDL 記事登録ID
    4833173
  • NDL 雑誌分類
    ZM35(科学技術--物理学)
  • NDL 請求記号
    Z15-1
  • データ提供元
    CJP書誌  NDL  J-STAGE 
ページトップへ