都市ごみ流動層炉における間欠運転と廃熱ボイラの最適制御 Optimum Control of Waste Heat Boiler and On-Off Operation of Fluidized Bed Incinerator being Supplied with of Municipal Solid Wastes

この論文にアクセスする

この論文をさがす

著者

抄録

都市ごみ流動層炉の特性を生かし, 廃熱ボイラの熱効率向上のために実炉を用いて実験した.その結果, 必要以上の蒸気を発生させないために, 流動状態を瞬時に停止する制御法が有効であることが確認された.<BR>また, 夜間はごみの焼却を停止して砂の保有熱で蒸気圧力を保持し, 日中は最大能力で燃焼する流動層炉の毎日の間欠運転が余剰電力を生み出すのに有効であることがわかった.

Experiments were conducted to improve the thermal efficiency of a waste heat boiler fitted to a commercial fluidized bed incinerator being supplied with municipal solid waste (MSW). As a result, it was found that the control method, which is a operation of stopping fluidization instantaneously for the purpose of preventing excess steam generation, is effective. Furthermore, the daily on-off operation of a fluidized bed incinerator, which is the operation of maintaining the operational steam pressure using the heat accumulation in sand without feeding MSW at night and performing maximum combustion in the daytime, was confirmed to be effective for producing excess electric power.

収録刊行物

  • 化学工学論文集  

    化学工学論文集 22(6), 1307-1312, 1996-11-20 

    The Society of Chemical Engineers, Japan

参考文献:  1件