セパレータタイプ高性能フィルタ内部の流れと圧力損失特性の解析 -3次元モデル Characteristics of Flow and Pressure Drop of Separator Type HEPA Filter-Three Dimensional Model

この論文にアクセスする

この論文をさがす

著者

    • 趙 相俊 CHO Sang Joon
    • 広島大学工学部第三類化学工学講座 Department of Chemical Engineering, Faculty of Engineering, Hiroshima University
    • 大谷 吉生 OTANI Yoshio
    • 金沢大学工学部物質化学工学科 Department of Chemistry and Chemical Engineering, Faculty of Engineering, Kanazawa University
    • 江見 準 EMI Hitoshi
    • 金沢大学工学部物質化学工学科 Department of Chemistry and Chemical Engineering, Faculty of Engineering, Kanazawa University

抄録

Separator-type HEPA filters are composed of the elements which have square cross section bounded by the two separator walls and partitioned by the filter medium. Therefore, it is possible to characterize the pressure drop of a separator type air filter unit by studying the pressure drop of this filter element. In the present work, air flow distribution and the pressure drop of the filter element were studied through numerical calculations and experiments with the three-dimensional model filter. It was found that an optimum separator height is about 3.0 mm being independent of filter inlet air velocity. At a small separator height, the pressure drop significantly decreases with increasing separator pleating angle, while at a large separator height the pleating angle little affects the pressure drop. The separator-pleating angle and the media resistance coefficient affect the distribution of airflow velocity through the filter media only in the direction of the main air flow.

収録刊行物

  • エアロゾル研究 = Journal of aerosol research  

    エアロゾル研究 = Journal of aerosol research 11(4), 327-336, 1996-12-20 

    日本エアロゾル学会

参考文献:  6件

参考文献を見るにはログインが必要です。ユーザIDをお持ちでない方は新規登録してください。