NMR Manometer for Clamp Pressure Cells

この論文にアクセスする

この論文をさがす

著者

抄録

A simple manometer for measuring pressures up to 15 kbar in clamp type cells is presented on the basis of the pressure dependence of zero-field NMR frequencies v in such ferromagnets as EuO and fcc Co. A narrow and intense <SUP>153</SUP>Eu NMR in EuO is suitable for a NMR manometer with an accuracy of 0. 1 kbar at 4. 2 K. An intense, but rather broad <SUB>59</SUB>Co NMR in fcc Co can be used in temperatures between 4. 2-300 K, where d v/dP is nearly independent of temperature. It is shown by using NMR manometers that the presssure in a clamp cell remains constant below 77 K.

収録刊行物

  • 高圧力の科学と技術 = The Review of high pressure science and technology

    高圧力の科学と技術 = The Review of high pressure science and technology 7, 1505-1507, 1998

    The Japan Society of High Pressure Science and Technology

参考文献:  8件中 1-8件 を表示

  • <no title>

    JENNINGS L. D.

    Phys. Rev. 112, 31, 1968

    被引用文献1件

  • <no title>

    THOMPSON T. P.

    Rev. Sci. Instrum. 55, 231, 1984

    被引用文献1件

  • <no title>

    HIRAOKA K.

    J. Sci. Hiroshima Univ. A50, 1, 1986

    被引用文献1件

  • <no title>

    TSUJIMURA A.

    J. Sci. Hiroshima Univ. A31, 1, 1967

    被引用文献1件

  • <no title>

    BOYD E. L.

    Phys. Rev. 145, 174, 1966

    被引用文献1件

  • <no title>

    HIRAOKA K.

    Solid State Commun. 52, 479, 1984

    被引用文献1件

  • <no title>

    FUJIWARA H.

    Rev. Sci. Instrum. 51, 1345, 1980

    DOI 被引用文献4件

  • <no title>

    REYES A. P.

    Rev. Sci. Instrum. 63, 3120, 1992

    DOI 被引用文献5件

各種コード

  • NII論文ID(NAID)
    10002694503
  • NII書誌ID(NCID)
    AN10452913
  • 本文言語コード
    ENG
  • 資料種別
    ART
  • ISSN
    0917639X
  • NDL 記事登録ID
    4494281
  • NDL 雑誌分類
    ZP1(科学技術--化学・化学工業)
  • NDL 請求記号
    Z17-1589
  • データ提供元
    CJP書誌  NDL  J-STAGE 
ページトップへ