空調用アコーディオン形オフセットフィン熱交換器の開発 Development of an Accordion-type Offset-fin Heat Exchanger for Air-conditioners

この論文にアクセスする

この論文をさがす

著者

抄録

To reduce the depth of the indoor heat exchanger in room air-conditioners, we studied fin and tube heat exchangers, and found that we could make the heat transfer coefficient of fins 30% higher than of conventional fins by reducing louver width and fin pitch.<br>We also improved water drainage on the surface of the fins by adopting accordion-type offset-fin heat exchangers.<br>We found that the material cost of a heat exchanger was minimized when the heat exchanger had a tube 7 mm in diameter, and we could increase the heat transter coefficient of the refrigerant side by developing a new grooved tube 7 mm in diameter.<br>We succeeded in making the heat exchanger 40% thinner than conventional types.

収録刊行物

  • 日本冷凍協会論文集  

    日本冷凍協会論文集 12(2), 219-224, 1995-07-31 

    Japan Society of Refrigerating and Air Conditioning Engineers