Development of an Accordion-type Offset-fin Heat Exchanger for Air-conditioners

Bibliographic Information

Other Title
  • 空調用アコーディオン形オフセットフィン熱交換器の開発

Search this article

Abstract

To reduce the depth of the indoor heat exchanger in room air-conditioners, we studied fin and tube heat exchangers, and found that we could make the heat transfer coefficient of fins 30% higher than of conventional fins by reducing louver width and fin pitch.<br>We also improved water drainage on the surface of the fins by adopting accordion-type offset-fin heat exchangers.<br>We found that the material cost of a heat exchanger was minimized when the heat exchanger had a tube 7 mm in diameter, and we could increase the heat transter coefficient of the refrigerant side by developing a new grooved tube 7 mm in diameter.<br>We succeeded in making the heat exchanger 40% thinner than conventional types.

Journal

Citations (1)*help

See more

References(10)*help

See more

Details 詳細情報について

  • CRID
    1390001204666314112
  • NII Article ID
    10002713361
  • NII Book ID
    AN10035654
  • DOI
    10.11322/tjsrae.12.219
  • ISSN
    2185789X
    13444905
  • Text Lang
    ja
  • Data Source
    • JaLC
    • CiNii Articles
  • Abstract License Flag
    Disallowed

Report a problem

Back to top