2.5MHzで出力1kwのフルブリッジ形MOS-FET式電力インバータの電力損失と効率 Power loss and efficiency in full-bridged MOS-FET DC-to-RF Power Inverter with output Power of 1kW at 2.5MHz

この論文にアクセスする

この論文をさがす

著者

抄録

This paper describes the power loss and efficiency in full-bridged MOS-FET arrays, each consisting of parallel connected MOS-FETs, and those in an output power transformer whose output power is fed to a load at an output power of 1kW at a frequency of 2.5MHz. The power losses within the MOS-FET arrays and output power transformer are estimated based on their thermal resistances which have separately been obtained from the measurement. The drain efficiency is thus obtained from the DC input power, RF output power, and estimated power losses. The output power of the MOS-FET arrays was 1300 to 1400W at a drain efficiency of 74 to 79% at a frequency of 2.5MHz when the DC voltage was 180V.

収録刊行物

  • 電気学会論文誌. D, 産業応用部門誌 = The transactions of the Institute of Electrical Engineers of Japan. D, A publication of Industry Applications Society  

    電気学会論文誌. D, 産業応用部門誌 = The transactions of the Institute of Electrical Engineers of Japan. D, A publication of Industry Applications Society 117(1), 35-43, 1997-01 

    The Institute of Electrical Engineers of Japan

参考文献:  15件

参考文献を見るにはログインが必要です。ユーザIDをお持ちでない方は新規登録してください。

被引用文献:  3件

被引用文献を見るにはログインが必要です。ユーザIDをお持ちでない方は新規登録してください。

各種コード

  • NII論文ID(NAID)
    10002723602
  • NII書誌ID(NCID)
    AN10012320
  • 本文言語コード
    JPN
  • 資料種別
    ART
  • ISSN
    09136339
  • NDL 記事登録ID
    4106135
  • NDL 雑誌分類
    ZN31(科学技術--電気工学・電気機械工業)
  • NDL 請求記号
    Z16-1608
  • データ提供元
    CJP書誌  CJP引用  NDL  J-STAGE 
ページトップへ