鉄道車両用主電動機の絶縁診断試験の検証 Verification of insulation tests for traction motor

この論文にアクセスする

この論文をさがす

著者

抄録

As for traction motor for railway vehicle, over fifty thousands DC motors are used only in Japan Railways Companies. Insulation breakdown is one of the biggest problem for traction motor and various kind of insulation tests are carried out for every motors at the time of overhaul. The methods and the way of these insulation tests are determined about thirty years ago or more. Materials of insulation and how to compose these materials have progressed in these days. So it is important to research what kind of insulation test is suited for traction motor.<br>This time we made a research to estimate various kinds of insulation tests by carrying out dielectric breakdown test for over 150 motors. And this paper describes the result.

収録刊行物

  • 電気学会論文誌. D, 産業応用部門誌 = The transactions of the Institute of Electrical Engineers of Japan. D, A publication of Industry Applications Society  

    電気学会論文誌. D, 産業応用部門誌 = The transactions of the Institute of Electrical Engineers of Japan. D, A publication of Industry Applications Society 117(12), 1511-1516, 1997-12-01 

    The Institute of Electrical Engineers of Japan

参考文献:  10件

参考文献を見るにはログインが必要です。ユーザIDをお持ちでない方は新規登録してください。

各種コード

  • NII論文ID(NAID)
    10002725831
  • NII書誌ID(NCID)
    AN10012320
  • 本文言語コード
    JPN
  • 資料種別
    ART
  • ISSN
    09136339
  • NDL 記事登録ID
    4353658
  • NDL 雑誌分類
    ZN31(科学技術--電気工学・電気機械工業)
  • NDL 請求記号
    Z16-1608
  • データ提供元
    CJP書誌  NDL  J-STAGE 