軸発電システムの特性解析 Performance Analysis of Shaft Generator Systems

この論文にアクセスする

この論文をさがす

著者

抄録

A shaft generator system supplies electrical power required in a ship by using a part of the power produced by the main engine. Since the speed of the main engine can vary over a wide range, an externally commutated thyristor inverter, which has high reliability, is generally used to produce ac power with constant voltage and frequency.<br>In this paper, a set of system equations, by which the total harmonic distortion of the output voltage, for example, can be estimated, is derived first. The effects of leading angle of the inverter and the reactance of ac reactor located in the output-side of the inverter on the system performances and the operation limit of the system are then clarified. Moreover, a way of taking the system losses into account is proposed to obtain precise calculation results. Finally, the apparent power for the synchronous condenser to provide reactive power in the system is discussed.

収録刊行物

  • 電気学会論文誌. D, 産業応用部門誌 = The transactions of the Institute of Electrical Engineers of Japan. D, A publication of Industry Applications Society  

    電気学会論文誌. D, 産業応用部門誌 = The transactions of the Institute of Electrical Engineers of Japan. D, A publication of Industry Applications Society 118(10), 1209-1216, 1998-10 

    The Institute of Electrical Engineers of Japan

参考文献:  5件

参考文献を見るにはログインが必要です。ユーザIDをお持ちでない方は新規登録してください。

被引用文献:  8件

被引用文献を見るにはログインが必要です。ユーザIDをお持ちでない方は新規登録してください。

各種コード

  • NII論文ID(NAID)
    10002727397
  • NII書誌ID(NCID)
    AN10012320
  • 本文言語コード
    JPN
  • 資料種別
    ART
  • ISSN
    09136339
  • NDL 記事登録ID
    4565943
  • NDL 雑誌分類
    ZN31(科学技術--電気工学・電気機械工業)
  • NDL 請求記号
    Z16-1608
  • データ提供元
    CJP書誌  CJP引用  NDL  J-STAGE 
ページトップへ