Single-Phase Twice voltage PFC Converter for air conditioner

Bibliographic Information

Other Title
  • 力率改善型エアコン用単相倍電圧コンバータ回路
  • リキリツ カイゼンガタ エアコンヨウ タンソウ バイ デンアツ コンバータ カイロ

Search this article

Abstract

The active-filter is one of the most efficient methods to improve power factor. However, this method has problems such as increasing switching loss and switching noise.<br>This paper describes a new power factor correction (PFC) converter called “Partial-switching PFC”, which achieves power factor rate of 99% only by generating a single pulse in the power line cycle with high efficiency and low total harmonic distortion. Its application to our air-conditioners is described at the end.