Method of Determining Ignition Point for High Current Arc Ignition Test Method Specified in UL Standard
-
- Sugie Tadashi
- Hitachi Chemical Co
-
- Yamamoto Yoshikazu
- Hitachi Chemical Co
Bibliographic Information
- Other Title
-
- UL大電流アーク発火試験方法の発火点の判定方法
- UL ダイ デンリュウ アーク ハッカ シケン ホウホウ ノ ハッカテン ノ
Search this article
Abstract
High current arc ignition test is a method for testing flammabilty of polymeric insulating materials specified in UL standard. The determination of ignition point has a difficulty in distinguishing the ignition light of materials from the arc light of electrode itself. We analyzed the light generated during arc ignition test and found that mainly the ignition light of materials is generated while electrodes contact each other and that both light overlap while electrodes separate each other. We have designed a measuring circuit that can detect only the light generated while the electrodes contact each other.Accordingly the determination for ignition point was performed by measuring mainly the ignition light of materials with the circuit. Test results showed that the ignition point of several materials could be determined easily by using the light detecting circuit of our design.
Journal
-
- IEEJ Transactions on Fundamentals and Materials
-
IEEJ Transactions on Fundamentals and Materials 116 (7), 645-650, 1996
The Institute of Electrical Engineers of Japan
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282679576298368
-
- NII Article ID
- 10002819967
- 130006839339
-
- NII Book ID
- AN10136312
-
- ISSN
- 13475533
- 03854205
-
- NDL BIB ID
- 3985554
-
- Data Source
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed