Characteristics of Continuous CO Analyzers in Municipal Waste Incinerators

  • Tanikawa Noboru
    Tokyo Metropolitan Research Institute for Waste Management
  • Urano Kohei
    Laboratory of Safety and Environmental Engineering, Faculty of Engineering, Yokohama National University

Bibliographic Information

Other Title
  • 都市ごみ焼却施設における排ガス中の一酸化炭素自動計測器の特性
  • トシ ゴミ ショウキャク シセツ ニ オケル ハイガスチュウ ノ 1サンカ タ

Search this article

Abstract

Interference of 15 coexistent gases on the continuous CO analyzers with infrared absorption for the flue gas were investigated, and the measured values by the different types CO analyzers were compared at a municipal waste incinerator.<BR>CO2and N2O interfered with the CO analyzers. Then, there was a difference of about 4 ppm between the measured values from the double beam IR CO analyzer and those from the single beam IR CO analyzer. In order to precisely measure low CO concentrations, it is necessary to correct the measured values from the CO analyzers by taking their characteristics and mean concentrations of CO2and N2O concentrations in the flue gas.