書誌事項
- タイトル別名
-
- Solubility Measurements of High Pressure CO2 into Polystyrene by Quartz Crystal Microbalance.
- スイショウ シンドウシ オ モチイタ ポリスチレン ニ タイスル 2サンカタン
この論文をさがす
抄録
In this paper, the ability of quartz crystal microbalance (QCM) was considered about in situ measurement in high pressure fluid. Solubility and adsorption of high pressure carbon dioxide (CO2) to polystyrene (PS) were measured using a QCM as a detector at pressures up to 17 MPa at 313. 2 K. The solubility and surface adsorption of CO2 increased almost linearly against activity of CO2. And it was found that the present method could be applied to higher pressure range than any other methods. The activity plot of solubility at various temperatures fell into one universal line. This may be very important because it suggests the possibility of obtaining the solubility at any temperature from only one measurement.
収録刊行物
-
- 高圧力の科学と技術
-
高圧力の科学と技術 6 (3), 176-181, 1997
日本高圧力学会
- Tweet
キーワード
詳細情報 詳細情報について
-
- CRID
- 1390282679359303424
-
- NII論文ID
- 10002848754
-
- NII書誌ID
- AN10452913
-
- ISSN
- 13481940
- 0917639X
-
- NDL書誌ID
- 4314837
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可