Result of Magnetic Shielding Experiment about Flow of Flux
-
- Sasakawa Takashi
- Railway Technical Research Institute
-
- Tagawa Naoto
- Railway Technical Research Institute
-
- Herai Toshiki
- Railway Technical Research Institute
-
- Tomita Masaru
- Railway Technical Research Institute
Bibliographic Information
- Other Title
-
- フラックスの流れに注目した磁気シールド試験結果
- フラックス ノ ナガレ ニ チュウモクシタ ジキ シールド シケン ケッカ
Search this article
Abstract
Magnetic shielding is an important task for superconducting magnetically levitated train. We previously proposed optimal design method of magnetic shielding for minimazation of magnetic shield weight. In this paper, we report the test result of the magnetic shielding facility based on the optimal design method. We can atain magnetic flux density less than 2mT in the region surrounded by magnetic shield, whose weight is lighter than any other test facility constructed previously.
Journal
-
- IEEJ Transactions on Industry Applications
-
IEEJ Transactions on Industry Applications 118 (4), 501-510, 1998