Effect of Suspended Particles on Ultrafiltration Membrane.
-
- YASUMOTO HIDEYUKI
- Department of Bioengineering, Soka University
-
- SASAKI MASAYOSHI
- Department of Bioengineering, Soka University
-
- NIITSU TAKASHI
- Department of Bioengineering, Soka University
-
- INOUE HAKUAI
- Department of Bioengineering, Soka University
Bibliographic Information
- Other Title
-
- 管型限外ろ過膜を使ったろ過での懸濁粒子の影響の研究
- カンガタ ゲンガイ ロカ マク オ ツカッタ ロカ デ ノ ケンダク リュウシ
Search this article
Abstract
The effect of suspended particles on the tubular membrane filtration of dextran solutions is studied, and the permeation flux is measured. In the case of operation with a horizontal membrane module, the permeation flux decreases with increasing particle concentration for low fluid circulation rates, and for high circulation rates it increases with particle concentration.<BR>On the other hand, in case of the up-flow operation with a vertical membrane, the permeation flux increases with particle concentration for all circulation flow rates.<BR>The mechanism of the effect of particles on the permeation flux is discussed based on the behavior of particles in a tubular liquid flow.