放射光を用いた乳房撮影における乳腺平均吸収線量 Average Glandular Dose in Synchrotron Radiation Mammography

この論文にアクセスする

この論文をさがす

著者

    • 藤崎 達也 FUJISAKI Tatsuya
    • 茨城県立医療大学 保健医療学部 放射線技術科学科 Department of Radiological Sciences, Ibaraki Prefectural University of Health Sciences
    • 西村 克之 NISHIMURA Katsuyuki
    • 茨城県立医療大学 保健医療学部 放射線技術科学科 Department of Radiological Sciences, Ibaraki Prefectural University of Health Sciences
    • 阿部 慎司 ABE Shinji
    • 茨城県立医療大学 保健医療学部 放射線技術科学科 Department of Radiological Sciences, Ibaraki Prefectural University of Health Sciences
    • 関根 紀夫 SEKINE Norio
    • 茨城県立医療大学 保健医療学部 放射線技術科学科 Department of Radiological Sciences, Ibaraki Prefectural University of Health Sciences
    • 高橋 義一 TAKAHASHI Yoshikazu
    • 茨城県立医療大学 保健医療学部 放射線技術科学科 Department of Radiological Sciences, Ibaraki Prefectural University of Health Sciences
    • 稲田 哲雄 INADA Tetsuo
    • 茨城県立医療大学 保健医療学部 放射線技術科学科 Department of Radiological Sciences, Ibaraki Prefectural University of Health Sciences
    • 齋藤 秀敏 SAITOH Hidetoshi
    • 東京都立保健科学大学 保健科学部 放射線学科 Department of Radiologial Sciences, Tokyo Metropolitan College of Health Sciences
    • 浦橋 信吾 URAHASHI Shingo
    • 日本大学大学院 理工学研究科 医療・福祉工学 Department of Medical & Welfare's Engineering, College of Science & Technology, Nihon University

抄録

Synchrotron radiation (SR) has the properties of both high intensity and monochromaticity which cannot be obtained with conventional X-ray generated by an X-ray tube. Although studies on mammography as an application of SR to medical diagnosis have been performed, there has been little work about the dependences of glandular dose on X-ray energy, breast compositions and breast thickness.<BR>It is difficult to measure the average glandular dose directly, so we calculated conversion factors to obtain average dose from incident air kerma using Monte Carlo simulation.<BR>In this study, the following results were obtained.: (1) A difference of 1 keV has a significant effect on the average glandular dose. (2) The average glandular dose in young age is about 50 % higher than in old age when the same absorbed dose is applied in phosphor layer. (3) The average glandular dose required in mammography is less dependent on the X-ray energy than the air kerma.