Clear Flaw Image Construction in Eddy Current Nondestructive Testing Using CT Technique
-
- Hoshikawa Hiroshi
- Nihon University
-
- Koyama Kiyoshi
- Nihon University
Bibliographic Information
- Other Title
-
- CT技術を利用した渦流探傷における鮮明なきず画像表示
- CT ギジュツ オ リヨウ シタ カリュウタンショウ ニ オケル センメイ ナ キズガゾウ ヒョウジ
Search this article
Abstract
Flaw images have recently been utilized in eddy current nondestructive testing in order to improve the evaluation accuracy of the surface flaw depth in the test material. The conventional eddy current testing can provide only blurred flaw images because of the expansion of the eddy current induced in the test material depending on the diameter of the circular test coil. As a result, eddy current testing has mainly been applied only to detect flaws and not to evaluate flaws in nondestructive testing.<br>The authors have applied CT inversion technique to the flaw signal by a thin tangential test coil in eddy current nondestructive testing in order to obtain clear flaw images. Since the flaw signals obtained by eddy current testing are totally different from those from X-ray projection, the authors have converted the eddy current testing signals into those analogous to Radon transform and applied CT inversion technique to the resulting signals. The experimental results have indicated that the CT inversion technique provides far clearer flaw images and higher possibility of quantitative flaw evaluation than the conventional method.
Journal
-
- IEEJ Transactions on Industry Applications
-
IEEJ Transactions on Industry Applications 119 (11), 1361-1370, 1999
The Institute of Electrical Engineers of Japan
- Tweet
Details 詳細情報について
-
- CRID
- 1390001204659596672
-
- NII Article ID
- 10004297468
-
- NII Book ID
- AN10012320
-
- ISSN
- 13488163
- 09136339
-
- NDL BIB ID
- 4891919
-
- Data Source
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed