出力電圧歪みの無い軸発電システムの研究 A Shaft Generator System without Output Voltage Distortion

この論文にアクセスする

この論文をさがす

著者

抄録

A shaft generator system, which consists of a shaft generator, a rectifier, an externally commutated thyristor inverter, an ac reactor, and a synchronous condenser, is being increasingly used mainly in large ships. Conventional type of the shaft generator system has a fundamental drawback of involving a large amount of harmonics in the output voltage waveform.<br>In this paper novel and simple circuit configurations are proposed to realize a shaft generator system without output voltage distortion. In order to cancel out the subtransient inductance of the synchronous condenser, by which voltage distortion is caused in the event of commutation of inverter, we propose a new system equipped with a duplex reactor instead of ac reactor. A set of system equations for the proposed system is then given, and the steady-state characteristics of the system are discussed. The effectiveness of the proposed system was confirmed with the experimental investigations. The apparent power of the duplex reactor is also discussed.

収録刊行物

  • 電気学会論文誌. D, 産業応用部門誌 = The transactions of the Institute of Electrical Engineers of Japan. D, A publication of Industry Applications Society  

    電気学会論文誌. D, 産業応用部門誌 = The transactions of the Institute of Electrical Engineers of Japan. D, A publication of Industry Applications Society 119(12), 1549-1555, 1999-12-01 

    The Institute of Electrical Engineers of Japan

参考文献:  4件

参考文献を見るにはログインが必要です。ユーザIDをお持ちでない方は新規登録してください。

被引用文献:  13件

被引用文献を見るにはログインが必要です。ユーザIDをお持ちでない方は新規登録してください。

各種コード

  • NII論文ID(NAID)
    10004297749
  • NII書誌ID(NCID)
    AN10012320
  • 本文言語コード
    JPN
  • 資料種別
    ART
  • ISSN
    09136339
  • NDL 記事登録ID
    4924154
  • NDL 雑誌分類
    ZN31(科学技術--電気工学・電気機械工業)
  • NDL 請求記号
    Z16-1608
  • データ提供元
    CJP書誌  CJP引用  NDL  J-STAGE 
ページトップへ