Higher Order Harmonic Loss Currents through Water Tree Cross-Linked Polyethylene and Non-Linear Electrical Conduction

Bibliographic Information

Other Title
  • 水トリー劣化架橋ポリエチレンの高調波電流と非線形電気伝導
  • ミズ トリー レッカ カキョウ ポリエチレン ノ コウチョウハ デンリュウ ト ヒセンケイ デンキ デンドウ

Search this article

Abstract

A comparison of the observed relative magnitude of the 3rd harmonic wave to the fundamental one of ac loss current I3/I1 and phase of the 3rd harmonic wave θ3 with the calculated ones has been done for water tree cross-linked polyethylene. The model used for this calculation takes account of non-linear electrical conduction mechanism in the water tree region and contains two parameters; one of them is a parameter characterizing the effect of electric field on the non-linear electrical conduction and the other is a conductivity at low electric fields depending on frequency of applied voltage. It has been found that this model can explain qualitatively the changes in I3/I1 and θ3 for applied voltage and its frequency.