A Simple Acrylate Fiber Sampler for Stream Periphyton.
-
- TANIDA Kazumi
- College of Integrated Arts and Sciences, Osaka Prefecture University
-
- MITSUHASHI Hiromune
- Museum of Nature and Human Activities
-
- FUJITANI Toshihito
- Graduated School of Agriculture, Osaka Prepecture University
Bibliographic Information
- Other Title
-
- 特殊アクリル繊維による付着藻類定量法
- トクシュ アクリル センイ ニ ヨル フチャク ソウルイ テイリョウホウ
Search this article
Abstract
A simple method of measuring the amount of chlorophyll a in epilithic algae was newly developed. To scour the algae, we used a special acrylate fiber (Micro-cloth; Koyo Co. Ltd., Tokyo : by Shaleria of Asahi Chemical Co.) and a rubber plate with a hole 25 mm in diameter. The accuracy of the new method was tested in comparison with the traditional method of scrap-ing a rectangular area of 50 by 50 mm with a toothbrush, resulting in similar measured values between these two methods (R2=0.986 ; y=1.029x ; x : measured values by the toothbrush method, y : those by Micro-cloth method). This new simple method is appropriate for determining the micro-distribution of epilithic algae.
Journal
-
- Japanese Journal of Limnology (Rikusuigaku Zasshi)
-
Japanese Journal of Limnology (Rikusuigaku Zasshi) 60 (4), 619-624, 1999
The Japanese Society of Limnology
- Tweet
Details 詳細情報について
-
- CRID
- 1390001204059483776
-
- NII Article ID
- 10004483858
-
- NII Book ID
- AN0024866X
-
- ISSN
- 18824897
- 00215104
- http://id.crossref.org/issn/00215104
-
- NDL BIB ID
- 5315364
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed