大型ヘリカル装置(Large Helical Device)プラズマ対向壁の壁洗浄効果 Wall Conditioning Effects of Large Helical Device

この論文にアクセスする

この論文をさがす

著者

抄録

For Large Helical Device, LHD, first cycle and second cycle experiments were conducted in 1998. Before each cycle experiments, SS316L samples were installed at the inner wall along poloidal direction. After the experiments, these samples were extracted, and the changes of surface morphology, atomic composition and gas desorption were investigated.<BR>After the first cycle experiments, dominant erosion and deposition of wall materials were observed, and the oxygen impurity level at the surface was considerably large. After the second cycle experiments, erosion and deposition almost disappeared, and the thickness of oxide layer largely decreased. In addition, the amount of desorbed impurity gas was reduced, compared with the case of first cycle experiments. In the second cycle experiments, it was seen that the plasma stored energy largely increased due to the reduction of the radiation power. The impurity level at the inner wall was largely reduced by the second cycle experiments.

収録刊行物

  • 真空  

    真空 43(3), 223-226, 2000-03-20 

    The Vacuum Society of Japan

参考文献:  7件

参考文献を見るにはログインが必要です。ユーザIDをお持ちでない方は新規登録してください。

各種コード

  • NII論文ID(NAID)
    10004561571
  • NII書誌ID(NCID)
    AN00119871
  • 本文言語コード
    JPN
  • 資料種別
    SHO
  • ISSN
    05598516
  • NDL 記事登録ID
    5360865
  • NDL 雑誌分類
    ZN15(科学技術--機械工学・工業--流体機械)
  • NDL 請求記号
    Z16-474
  • データ提供元
    CJP書誌  NDL  J-STAGE 
ページトップへ