Inconsistencies of Microcalcification Specks in Phantoms Approved by the American College of Radiology for Mammography Accreditation

この論文にアクセスする

この論文をさがす

著者

抄録

<I>PURPOSE</I>: To quantitatively demonstrate inconsistencies in microcalcification specks in RMI 156phantoms approved by the American College of Radiology (ACR) for use with their mammography accreditation program.<BR><I>MATERIALS AND METHODS</I>: Signal intensities of the largest three specks (Cl,540, μm; C2,400pm; C3,320 μm) were measured on images of 14 RMI 156 (version 4) phantoms. Three images were analyzed per phantom: a packaged image of the wax plate and two phantom images obtained at an optical density of 1.2 to 1.3. Phantom images were digitized using a VXR 12 scanner at a resolution of 85 μm and 8 bit/pixel. Speck signals were measured as the average pixel values using the NIH Image program (version 1.61).<BR><I>RESULTS</I>: Signal intensities of specks measured on phantom images were consistent with those measured on wax plate images, with an average correlation coefficient of 0.898 for the Cl groups and of 0.794 for the C3 groups. Overlap of speck sizes was found between different groups. Speck signals of some inserts showed considerable inconsistencies within a group. In some phantoms, signal intensities of specks in different groups overlapped to each other, and Cl and C2 groups were not clearly separated. In all 14 phantoms, speck signal intensities of the C3 group had a between phantom variance which was larger than the within phantom variance.<BR><I>CONCLUSION</I>: Microcalcification specks in RMI 156 phantoms of the same version were found to be substantially inconsistent in terms of size and intrinsic signal intensity. As lack of uniformity in specks within a phantom and between phantoms is not appropriate as a standard of image quality control, further quality control is apparently needed in manufacturing RMI 156 phantoms and also in approving specific phantoms.

収録刊行物

  • 医学物理 : 日本医学物理学会機関誌 = Japanese journal of medical physics : an official journal of Japan Society of Medical Physics  

    医学物理 : 日本医学物理学会機関誌 = Japanese journal of medical physics : an official journal of Japan Society of Medical Physics 20(1), 46-55, 2000-03-31 

    一般社団法人 日本医学物理学会

参考文献:  8件

参考文献を見るにはログインが必要です。ユーザIDをお持ちでない方は新規登録してください。

被引用文献:  1件

被引用文献を見るにはログインが必要です。ユーザIDをお持ちでない方は新規登録してください。

各種コード

  • NII論文ID(NAID)
    10004573823
  • NII書誌ID(NCID)
    AA11580542
  • 本文言語コード
    ENG
  • 資料種別
    OTR
  • ISSN
    13455354
  • NDL 記事登録ID
    5673635
  • NDL 雑誌分類
    ZS45(科学技術--医学--放射線医学)
  • NDL 請求記号
    Z19-1395
  • データ提供元
    CJP書誌  CJP引用  NDL  J-STAGE 
ページトップへ