防じんマスク評価用粒子発生装置 An Aerosol Generator for Certification Test of Dust Respirators

この論文にアクセスする

この論文をさがす

著者

抄録

The national approval test for dust respirator certification in Japan requires that air containing quartz particles less than 2 μm in diameter be used as a test aerosol. In view of the international accordance of respirator certification, we developed a new sodium chloride aerosol and oil mist aerosol generator as an alternative. We confirmed that the concentration of generated particles was 33.5 ± 3.4 mg/m<SUP>3</SUP> for the sodium chloride aerosol and 29.8 ± 0.4 mg/m<SUP>3</SUP> for DOP aerosol. Further we measured the size distribution of generated particles using SMPS for 8 hours. Measured count median diameter of generated particles was 0.078 μm for the sodium chloride aerosol and 0.189 μm for DOP aerosol. The geometric standard deviation was 1.773 for the sodium chloride aerosol and 1.581 for DOP aerosol.

収録刊行物

  • エアロゾル研究 = Journal of aerosol research  

    エアロゾル研究 = Journal of aerosol research 15(2), 138-142, 2000-06-20 

    日本エアロゾル学会

参考文献:  5件