Relationship between the Hydrophobicity of Cations and the Cationic Response of a Plasticized Poly(vinyl chloride) Membrane Electrode with no Added Ion-Exchanger.
-
- MASADOME Takashi
- Department of Chemical Science and Engineering, Ariake National College of Technology
-
- IMATO Toshihiko
- Department of Chemical Systems and Engineering, Graduate School of Engineering, Kyushu University
-
- WAKIDA Shin-ichi
- Department of Energy and the Environment, Osaka National Research Institute, Agency of Industrial Science and Technology, Ministry of International Trade and Industry
-
- HIGASHI Kunishige
- Department of Energy and the Environment, Osaka National Research Institute, Agency of Industrial Science and Technology, Ministry of International Trade and Industry
-
- ASANO Yasukazu
- Laboratory of Chemistry, Department of General Education, Ariake National College of Technology
Search this article
Abstract
The potential response of an electrode based on an o-nitrophenyl octyl ether (o-NPOE)-plasticized poly(vinyl chloride) (PVC) membrane with no added ion-exchanger to several cations of different hydrophobicity was examined. Furthermore, the hydrophobicity of the cations was evaluated by measuring the selectivity coefficient, KPotNa,cation, of a sodium ion-selective electrode based on an o-NPOE-plasticized PVC membrane containing a cation exchanger, since the selectivity coefficient is closely related to hydrophobicity of the ions. From these results, the o-NPOE-plasticized PVC membrane electrode with no added ion-exchanger showed a Nernstian response to the cations for which the sodium ion-selective electrode has a selectivity coefficient, KPotNa,cation, of more than 106.0. In addition, an electrode based on only the plasticizer (o-NPOE) was fabricated by using an ion-sensitive field-effect transistor (ISFET); the response of the electrode to the cations was examined in order to evaluate the contribution of the plasticizer, itself, to the electrode response of the PVC membrane electrode with no added ion-exchanger. From the response of the o-NPOE-plasticized PVC membrane electrode and that of the ISFET electrode based on only the plasticizer to the cations, the response mechanism of the o-NPOE-plasticized PVC membrane electrode with no added ion-exchanger to the hydrophobic cations is discussed.
Journal
-
- Analytical Sciences
-
Analytical Sciences 16 (4), 383-389, 2000
The Japan Society for Analytical Chemistry
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282679233113216
-
- NII Article ID
- 130004440243
- 10004706044
-
- NII Book ID
- AA10500785
-
- COI
- 1:CAS:528:DC%2BD3cXivFShs74%3D
-
- ISSN
- 13482246
- 09106340
-
- NDL BIB ID
- 5345159
-
- Text Lang
- en
-
- Data Source
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed