A Carbon Dioxide Gas Sensor Based on Solid Electrolyte for Air Quality Control
-
- Kaneyasu Kazunari
- FIGARO ENGINEERING INC.
-
- Otsuka Kazuyuki
- FIGARO ENGINEERING INC.
-
- Setoguchi Yasuhiro
- FIGARO ENGINEERING INC.
-
- Nakahara Takeshi
- FIGARO ENGINEERING INC.
-
- Sonoda Shigeyo
- FIGARO ENGINEERING INC.
-
- Aso Isao
- FIGARO ENGINEERING INC.
Bibliographic Information
- Other Title
-
- 空調用固体電解質型二酸化炭素センサの開発
- クウチョウヨウ コタイ デンカイシツガタ 2サンカタンソ センサ ノ カイハツ
Search this article
Abstract
A CO2 sensor was set up by using Na3Zr2Si2PO12 (NASICON) as a solid electrolyte, Li2CO3 as a carbonate phase. The EMF (Electromotive force) was linear to the logarithm of CO2 concentration and hardly depended on interfering gases by using a zeolite filter. The Δ EMF (EMFAir-EMFGas) was stable even after the test of unpowered exposure to a high humidity atmosphere. The CO2 monitor in which the CO2 concentration is calculated by the Δ EMF using a new renovating system of the standard EMF was developed as a monitor for air quality control. The output of the monitor indicated a good agreement with that of the usual NDIR analyzer at the field-test in the office.
Journal
-
- IEEJ Transactions on Sensors and Micromachines
-
IEEJ Transactions on Sensors and Micromachines 118 (2), 119-124, 1998
The Institute of Electrical Engineers of Japan
- Tweet
Details 詳細情報について
-
- CRID
- 1390282679437823104
-
- NII Article ID
- 10004833179
-
- NII Book ID
- AN1052634X
-
- ISSN
- 13475525
- 13418939
- http://id.crossref.org/issn/13418939
-
- NDL BIB ID
- 4392294
-
- Data Source
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed