Noise Measurement by Echo Integrator

この論文をさがす

抄録

A method to measure noise at the output of echo integrators has been developed for precise estimation of fisheries resources by acoustic means. This method is more practical than the method to measure noise at receiver output, because noise contribution can be easily compared withthe volume backscat-tering strength (SV) of fish and because there is less ambiguity in noise measurement. Also a conversion equation of the echo integrator output to the equivalent noise spectrum level isderived. This facilitates the comparison, for example, between different echo sounding system.We applied this method to a dual beam echo sounding system on board research vessel Kaiyo-maru, and confirmed that the difference in noise SV of 5 dB agreed with the theoretical prediction.

収録刊行物

被引用文献 (1)*注記

もっと見る

参考文献 (6)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘