低周波音による建具のがたつき始める音圧レベルについて

書誌事項

タイトル別名
  • On the Threshold Level of Rattling Fittings Due to Low Frequency Sound Pressure Level
  • トウコウ テイシュウハオン ニ ヨル タテグ ノ ガタツキ ハジメル オンアツ レベル ニ ツイテ

この論文をさがす

抄録

Half of the complaints against low frequency sound are structural one, such as rattling doors or windows. This paper describes about the laboratory experiments concerning rattling of doors or windows generated by infra and low frequency sound. The results are shown as follows.<br>(1) The threshold sound pressure levels of rattling doors and windows (hereinafter called TSR) are varying widely, <br>(2) TSR are determined by many factors; frequency of infra and low frequency sound, mass of the door or the window, type or variety of them, clearance between the door and the frame, and so on. But, the most important factor is the shutting condition of the door or the window, <br>(3) The “average-S.D.” of TSR on each frequency for all data; (Lrat, ave-S.D.) were calculated, Lrat, ave-S.D. showed a good correlation with “rattling threshold”, proposed in 1977, between 10 to 30Hz, <br>(4) By comparing the results of field measurements and the experimental level (Lrat, ave-S.D.), it became clear that the most of all sound pressure levels where structural complaints occurred, distributed above Lrat, ave-S.D..

収録刊行物

  • 騒音制御

    騒音制御 26 (2), 120-128, 2002

    公益社団法人 日本騒音制御工学会

被引用文献 (8)*注記

もっと見る

参考文献 (9)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ