Study on the Evaluation of Snow Load on Roof of livestock Buildings.
-
- KOBAYASHI Toshimichi
- Nikkoukinzoku corporation
-
- CHIBA Takahiro
- Nikkoukinzoku corporation
-
- TOMABECHI Tsukasa
- Hokkaido Institute of Technology
-
- HOSHIBA Shinji
- Rakunou Gakuen University
Bibliographic Information
- Other Title
-
- 畜舎施設における屋根上積雪荷重評価について
- チクシャ シセツ ニ オケル ヤネウエ セキセツ カジュウ ヒョウカ ニ ツイテ
Search this article
Abstract
In this study, we aimed to evaluate the snow load in order to make the construction cost of animal facilities lower in snow zones.<br>According to the investigation, we concluded as follows;<br>1) Snow sliding is more influenced by the contact angle than surface coarseness. Snow sliding easily takes place on roofs with high water shedding.<br>2) when animal facilities are designed, the roof slope should be more than 3/10 if corrugated painted steel sheet or fiber reinforced plastic are used. In the case of using fluorine films or C seed membrane, the slope more than 2/10 is enough.<br>3) The design snow load should be evaluated not only by water shedding characteristics of roofs but also by livestock housing systems such as stocking rates which may affect the roof surface temperature.
Journal
-
- Nogyo Shisetsu (Journal of the Society of Agricultural Structures, Japan)
-
Nogyo Shisetsu (Journal of the Society of Agricultural Structures, Japan) 32 (2), 69-77, 2001
The Society of Agricultural Structures, Japan
- Tweet
Details 詳細情報について
-
- CRID
- 1390001204351131648
-
- NII Article ID
- 130004097945
- 10008025414
-
- NII Book ID
- AN00201054
-
- ISSN
- 21860122
- 03888517
-
- NDL BIB ID
- 5925683
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL
- CiNii Articles
-
- Abstract License Flag
- Disallowed