上顎臼歯部インプラント術後評価のためのCT画像3次元表示法(3DCT)の検討 3 DCT Imaging Technique to Evaluate the Endosseous Implants in Maxillary Molar Region

この論文にアクセスする

この論文をさがす

著者

抄録

To observe details in postoperative endosseous implants in the maxillary molar region, a three-dimensional computed tomography (3 DCT) imaging technique was designed. CT examinations were performed on 4 patients in the follow-up stage. Oblique sagittal and oblique coronal imaging planes, which parallel the direction of implant fixtures, were measured using a multiplanar reformatting (MPR) technique. Cross-sectional reformatting slice images, and volume rendering crosscut images using the above imaging planes, were created in 9 implant fixtures, respectively. Sufficient 3 D images were obtained to evaluate the relationship between implant fixtures and the maxillary sinus cavity, three-dimensionally.3 DCT was a practical imaging technique to evaluate postoperative endosseous implants.<br/>

収録刊行物

  • 日本口腔インプラント学会誌 = Journal of Japanese Society of Oral Implantology

    日本口腔インプラント学会誌 = Journal of Japanese Society of Oral Implantology 14(3), 114-120, 2001-09-30

    公益社団法人 日本口腔インプラント学会

参考文献:  12件中 1-12件 を表示