「デンタルプレスケールシステム」の臨床応用に関する基礎的検討 : 第2報 プレスケール介在部位の変化が各歯咬合面積値・平均圧力値および咬合力値に及ぼす影響 Basic Study on "Dental Prescale System" : Part II. Concerning the Influence of Insertion Area on Occlusal Contact Area, Occlusal Pressure Average and Occlusal Force

この論文にアクセスする

この論文をさがす

著者

    • 中島 一憲 NAKAJIMA Kazunori
    • 日本大学歯学部歯科補綴学教室局部床義歯学講座 Department of Removable Partial Denture Prosthodontics, Nihon University School of Dentistry
    • 藤井 肇基 FUJII Toshiki
    • 日本大学歯学部歯科補綴学教室局部床義歯学講座 Department of Removable Partial Denture Prosthodontics, Nihon University School of Dentistry
    • 清水 信行 SHIMIZU Nobuyuki
    • 日本大学歯学部歯科補綴学教室局部床義歯学講座 Department of Removable Partial Denture Prosthodontics, Nihon University School of Dentistry
    • 小川 透 OGAWA Tohru
    • 日本大学歯学部歯科補綴学教室局部床義歯学講座 Department of Removable Partial Denture Prosthodontics, Nihon University School of Dentistry
    • 武田 友孝 TAKEDA Tomotaka
    • 日本大学歯学部歯科補綴学教室局部床義歯学講座 Department of Removable Partial Denture Prosthodontics, Nihon University School of Dentistry
    • 石上 惠一 ISHIGAMI Keiichi
    • 日本大学歯学部歯科補綴学教室局部床義歯学講座 Department of Removable Partial Denture Prosthodontics, Nihon University School of Dentistry
    • 大木 一三 OHKI Katsuzo
    • 日本大学歯学部歯科補綴学教室局部床義歯学講座 Department of Removable Partial Denture Prosthodontics, Nihon University School of Dentistry
    • 塩野 英昭 SHIONO Hideaki
    • 日本大学歯学部歯科補綴学教室クラウンブリッジ学講座 Department of Crown and Bridge Prosthodontics, Nihon University School of Dentistry
    • 五十嵐 孝義 IGARASHI Takayoshi
    • 日本大学歯学部歯科補綴学教室クラウンブリッジ学講座 Department of Crown and Bridge Prosthodontics, Nihon University School of Dentistry

抄録

The condition of contact and the distribution of occlusal force is important in the decision of the treatment method and the judgment of the effect of treatment in occlusal examination.<BR>This study was performed to investigate the influence of the insertion area of Prescale on the occlusal contact area, occlusal pressure average, and occlusal force for each tooth in normal persons, and the results were as follows:<BR>1. The occlusal contact area in forward teeth tended to increase when the insertion area of Prescale was moved forward.<BR>2. It was not more prominent than occlusal contact area though occlusal pressure average of forward teeth was increased when the insertion area of Prescale was moved forward.<BR>3. When the insertion area of Prescale was moved forward, the occlusal force of forward teeth tended to increase in the prominence compared with the occlusal contact area and occlusal pressure average.<BR>4. Due to the results, it was suggested that Dental Prescale is a more effective system to analyze occlusal force than occlusal contact area and occlusal pressure average.

収録刊行物

  • 日本補綴歯科學會雜誌 = The journal of the Japan Prosthodontic Society

    日本補綴歯科學會雜誌 = The journal of the Japan Prosthodontic Society 41(1), 52-60, 1997-02-01

    Japan Prosthodontic Society

参考文献:  56件中 1-56件 を表示

被引用文献:  16件中 1-16件 を表示

各種コード

  • NII論文ID(NAID)
    10008165226
  • NII書誌ID(NCID)
    AN00197911
  • 本文言語コード
    JPN
  • 資料種別
    ART
  • ISSN
    03895386
  • データ提供元
    CJP書誌  CJP引用  J-STAGE 
ページトップへ