純チタン鋳造床の臨床的評価 Clinical Evaluation of Pure Titanium Cast Plates

この論文にアクセスする

この論文をさがす

著者

抄録

Titanium is expected to be applied to prosthodontics because of its biocompatibility, but there are few reports on clinical investigation of titanium plate dentures. Pure titanium cast plate dentures have been made and clinically applied to 34 patients in Sakuma Dental Clinic since 1988. In 1995, 26 patients revisited the clinic, and the prognoses of their dentures were investigated.<BR>The results were as follows:<BR>1. In all cases, there was no discoloration, stain, or corrosion on the titanium plate surfaces.<BR>2. Two of 37 cast clasps were broken, but it had nothing to do with blow holes or porosities.<BR>3. These titanium cast plate dentures were satisfactory to both patients and dentists.