浸漬試験によるチタン溶出の評価

書誌事項

タイトル別名
  • In Vitro Assessment of Release from Titanium by Immersion Tests.

この論文をさがす

抄録

The purpose of this study was to examine the released titanium from casted isolated titanium and casted titanium coupled with other dental alloys (gold, Au-Ag-Pd, and Ag-Sn-Zn alloys) by the immersion test. After 3 weeks of immersion, titanium released into solutions were measured by ICP-AES.<BR>The results were as follows:<BR>1. Titanium released from isolated titanium test pieces in 1.28mM lactic acid were significantly more soluble than that in artificial saliva, saline solution, 1.28mM formic acid, and 1.28mM acetic acid.<BR>2. Titanium released from coupled titanium test pieces in lactic acid were more soluble than that in artificial saliva, saline solution. However, the released amount of titanium in lactic acid seemed to be attenuated by combining with gold, Au-Ag-Pd, and Ag-Sn-Zn alloys.

収録刊行物

被引用文献 (12)*注記

もっと見る

参考文献 (33)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ