歯列模型の咬合器装着時における咬頭嵌合位の再現性からみた咬合記録材の精度 Accuracy of Interocclusal Recording Materials for Reproducibility of Intercuspation on Mounting Stone Casts

この論文にアクセスする

この論文をさがす

著者

    • 篠田 浩人 SHINODA Hiroto
    • 昭和大学歯学部第一歯科補綴学教室 The First Department of Prosthodontics, School of Dentistry, Showa University
    • 割田 研司 WARITA Kenji
    • 昭和大学歯学部第一歯科補綴学教室 The First Department of Prosthodontics, School of Dentistry, Showa University
    • 川和 忠治 KAWAWA Tadaharu
    • 昭和大学歯学部第一歯科補綴学教室 The First Department of Prosthodontics, School of Dentistry, Showa University
    • 樋口 大輔 HIGUCHI Daisuke
    • 昭和大学歯学部第一歯科補綴学教室 The First Department of Prosthodontics, School of Dentistry, Showa University
    • 荒川 治子 ARAKAWA Haruko
    • 昭和大学歯学部第一歯科補綴学教室 The First Department of Prosthodontics, School of Dentistry, Showa University
    • 小西 潔 KONISHI Kiyoshi
    • 昭和大学歯学部第一歯科補綴学教室 The First Department of Prosthodontics, School of Dentistry, Showa University

抄録

The purpose of this study was to investigate the accuracy of interocclusal recording materials that reproduced intercuspation on mounting stone casts. A bridge type reference model, which could not maintain stable intercuspation without interocclusal records, was selected. The reference model was mounted on an articulator. Interocclusal records were taken on the reference model. The reference model could be separated from the articulator when interocclusal records were measured. For interocclusal records, which were made from PRESIDENT JET BITE, EXABITE, RAMITEC, Xantano, and NEW PLASTONE between the upper and lower reference models, the occlusal heights of the reference model on the left molar of the abutment side, anterior teeth, and right molar were measured using an IP-Checker. The PRESIDENT JET BITE, EXABITE, and RAMITEC elastic materials were studied to determine the influence on the recording range.<BR>The results were as follows:<BR>1. The occlusal height was higher for the left molar than the other sides when the recording range was the abutments; the occlusal height was higher for the left molar and the anterior teeth than for the right molar when the recording range was 1/3 dentition.<BR>2. The occlusal height of the elastic materials was lower than the nonelastic materials.<BR>3. The results suggested that interocclusal records made from addition type silicone rubber impression materials have the best reproducibility of intercuspation and a smaller recording range has greater reproducibility of intercuspation.

収録刊行物

  • 日本補綴歯科學會雜誌 = The journal of the Japan Prosthodontic Society

    日本補綴歯科學會雜誌 = The journal of the Japan Prosthodontic Society 41(6), 977-984, 1997-12-10

    Japan Prosthodontic Society

参考文献:  14件中 1-14件 を表示

被引用文献:  5件中 1-5件 を表示

各種コード

  • NII論文ID(NAID)
    10008168177
  • NII書誌ID(NCID)
    AN00197911
  • 本文言語コード
    JPN
  • 資料種別
    ART
  • ISSN
    03895386
  • データ提供元
    CJP書誌  CJP引用  J-STAGE 
ページトップへ