陶材焼付チタンクラウンの焼付強さおよび色調に及ぼすボンディングポーセレンとオペークポーセレンの配合比の影響 Effects of Bonding Porcelain/Opaque Porcelain Ratios on Bond Strength and Color Stability of Porcelain-Fused-to-Titanium Crown

この論文にアクセスする

この論文をさがす

著者

    • 石川 恵美 ISHIKAWA Emi
    • 日本歯科大学歯学部歯科補綴学教室第2講座 Department of Crown and Bridge, The Nippon Dental University School of Dentistry at Tokyo
    • 岡田 智雄 OKADA Tomoo
    • 日本歯科大学歯学部歯科補綴学教室第2講座 Department of Crown and Bridge, The Nippon Dental University School of Dentistry at Tokyo
    • 新谷 明喜 SHINYA Akiyoshi
    • 日本歯科大学歯学部歯科補綴学教室第2講座 Department of Crown and Bridge, The Nippon Dental University School of Dentistry at Tokyo
    • 山瀬 勝 YAMASE Masaru
    • 日本歯科大学歯学部歯科補綴学教室第2講座 Department of Crown and Bridge, The Nippon Dental University School of Dentistry at Tokyo
    • 砂田 徳保 SUNADA Noriyasu
    • 日本歯科大学歯学部歯科補綴学教室第2講座 Department of Crown and Bridge, The Nippon Dental University School of Dentistry at Tokyo
    • 川名 孝義 KAWANA Takayoshi
    • 日本歯科大学歯学部歯科補綴学教室第2講座 Department of Crown and Bridge, The Nippon Dental University School of Dentistry at Tokyo
    • 塚越 誠 TUKAKOSHI Makoto
    • 日本歯科大学歯学部歯科補綴学教室第2講座 Department of Crown and Bridge, The Nippon Dental University School of Dentistry at Tokyo
    • 横塚 繁雄 YOKOZUKA Shigeo
    • 日本歯科大学歯学部歯科補綴学教室第2講座 Department of Crown and Bridge, The Nippon Dental University School of Dentistry at Tokyo

抄録

To simplify the conventional porcelain application procedure, Bonding Porcelainand Opaque Porcelain of Super Porcelain TITAN (Noritake) were blended in this study. Powder of Bonding Porcelain and Opaque Porcelain were blended in weight ratios of 1: 1, 1: 2, and 2: 1, and then applied to titanium (KS50, Kobe Steel) and fired at one time. The bond strength of each compound was measured using the pull-out method. Measurement of color stability was performed in specimens, at variousthicknesses of the porcelain compounds and Body Porcelain, and differences from the standard color were calculated. Values for bond strength were significantlyhigher in compound specimens than "Opaque Porcelain only" specimens. Color stability varied depending on the blending ratio, but no color difference was observed only in monolayer specimens with the blending ratio of 1: 2 and thicknesses of 0.2 mm and 0.3 mm. From these findings, it was considerd that blending ratios hardly make any difference in color stability and that differencce inthe thickness of compound porcelain and Body porcelain affect color stability.

収録刊行物

  • 日本補綴歯科學會雜誌 = The journal of the Japan Prosthodontic Society

    日本補綴歯科學會雜誌 = The journal of the Japan Prosthodontic Society 42(1), 45-50, 1998-02-01

    Japan Prosthodontic Society

参考文献:  18件中 1-18件 を表示

被引用文献:  1件中 1-1件 を表示

各種コード

  • NII論文ID(NAID)
    10008168428
  • NII書誌ID(NCID)
    AN00197911
  • 本文言語コード
    JPN
  • 資料種別
    ART
  • ISSN
    03895386
  • データ提供元
    CJP書誌  CJP引用  J-STAGE 
ページトップへ