A Study on the Retention Force of Crowns. Influence of Thermal Cycling Cemented with Resin-modified Glass-ionomer Cements.

  • Ohmae Momoko
    Department of Crown and Bridge Prosthodontics, Nihon University School of Dentistry

Bibliographic Information

Other Title
  • クラウンの保持力に関する研究  レジンモディファイドグラスアイオノマーセメントのサーマルサイクルによる検討
  • Influence of Thermal Cycling Cemented with Resin-modified Glass-ionomer Cements
  • レジンモディファイドグラスアイオノマーセメントのサーマルサイクルによる検討

Search this article

Abstract

The purpose of this study was to clarify the long-term endurance of crown retention cemented with resin-modified glass-ionomer cements (RMGI) by thermal cycling simulating the oral environment.<BR>In this study, two kinds of cement, Fuji lute (FL) and Vitremer luting cement (VL), were selected, and Super bond C & B (SB), a resin system cement, and Fuji I (F I), a traditional GI cement, were also tested as controls.<BR>All specimens were cemented to metal abutments with each cement, and put through the thermal cycling (4°C-60°C-37°C) test 0 times, 5, 000 times, 10, 000 times, and 15, 000 times, respectively.<BR>The result was as follows:<BR>1. The retention force of crowns cemented with FL showed little variation due to thermal cycling.<BR>2. The retention force of crowns cemented with VL increased due to thermal cycling.<BR>3. After 15, 000 times of thermal cycling, the values of FL and VL were similar to the value of SB, and these were about two times that of F I.

Journal

Citations (2)*help

See more

References(43)*help

See more

Details 詳細情報について

Report a problem