インプラント作業模型の寸法精度 : 支台間の傾斜の影響について The Accuracy of Working Casts for Implants : Effect of Inclination of Implant Abutment

この論文にアクセスする

この論文をさがす

著者

    • 石浦 雄一 ISHIURA Yuichi
    • 昭和大学歯学部第一歯科補綴学教室 The First Department of Prosthodontics, School of Dentistry, Showa University

抄録

The purpose of this study was to investigate the accuracy of working casts made from two types of model, aparallel type and an angled type. Athree-dimensional measuring microscope was used to measure reference points on the master model and working casts.<BR>The master model was made from metal, and standard points A, B and C were located on the base of the master model. Reference points were provided on the occlusal surface and on the measuring jigs for implants.Impressions were taken using a custom tray and additional type silicone impression material, and working casts were made. Then the working casts were measured and compared to the master model.<BR>The results were as follows:<BR>1. In the implant area the distance between the two implants was greater than that of the master model for both types of working casts.<BR>2. Clockwise rotation of the implants was observed in both types of working casts.<BR>3. For the angled type working casts, reference points of the remaining teeth moved to a lower position.

収録刊行物

  • 日本補綴歯科學會雜誌 = The journal of the Japan Prosthodontic Society

    日本補綴歯科學會雜誌 = The journal of the Japan Prosthodontic Society 43(5), 809-820, 1999-10-10

    Japan Prosthodontic Society

参考文献:  39件中 1-39件 を表示

被引用文献:  4件中 1-4件 を表示