光導波路型ポッケルスセンサによる沿面放電直下の電界計測 Electric Field Measurement just under Surface Discharge by Optical-waveguide Pockels Sensors

この論文にアクセスする

この論文をさがす

著者

抄録

Surface discharge is one of the main phenomena in the fault of electric apparatus, but is not cleared yet. The electric field measurement in and around a corona streamer while the surface discharge creeps is greatly helpful for analyzing it. There is optical measurement technique for electric fields by using Pockels crystal, and an optical waveguide technique has been successfully introduced to miniaturize the sensors. The electric field measurement just under the surface discharge is tried with the optical waveguide Pockels sensor installed on a PMMA plate and output signals according to its development are obtained.

収録刊行物

  • 電気学会論文誌. A, 基礎・材料・共通部門誌 = The transactions of the Institute of Electrical Engineers of Japan. A, A publication of Fundamentals and Materials Society

    電気学会論文誌. A, 基礎・材料・共通部門誌 = The transactions of the Institute of Electrical Engineers of Japan. A, A publication of Fundamentals and Materials Society 122(7), 633-638, 2002-07-01

    一般社団法人 電気学会

参考文献:  8件中 1-8件 を表示

各種コード

  • NII論文ID(NAID)
    10008847582
  • NII書誌ID(NCID)
    AN10136312
  • 本文言語コード
    JPN
  • 資料種別
    ART
  • ISSN
    03854205
  • NDL 記事登録ID
    6204512
  • NDL 雑誌分類
    ZN31(科学技術--電気工学・電気機械工業)
  • NDL 請求記号
    Z16-793
  • データ提供元
    CJP書誌  NDL  J-STAGE 
ページトップへ