Evaluation of blood loss in trans-urethral resection of the prostate with HemoCue Plasma Low Hemoglobin

  • YOKOYAMA Takeshi
    Department of Anesthesiology and Critical Care Medicine, Kochi Medical School
  • YAMASHITA Koichi
    Department of Anesthesiology and Critical Care Medicine, Kochi Medical School
  • KOMATSU Kyoko
    Department of Anesthesiology, Faculty of Medicine, The University of Tokyo
  • KITAOKA Noriko
    Department of Anesthesiology and Critical Care Medicine, Kochi Medical School
  • MANABE Masanobu
    Department of Anesthesiology and Critical Care Medicine, Kochi Medical School
  • NISHIYAMA Tomoki
    Department of Anesthesiology, Faculty of Medicine, The University of Tokyo

Bibliographic Information

Other Title
  • 経尿道的前立腺切除術における出血量の評価:ヘモキュープラズマローヘモグロビンによる潅流排液中のヘモグロビン濃度測定
  • ヘモキュープラズマローヘモグロビン<sup>TM</sup>による灌流排液中のヘモグロビン濃度測定

Search this article

Abstract

We evaluated the blood loss of 24 TUR-P patients by measuring hemoglobin (Hb) concentration in waste irrigation fluid with HemoCue Plasma/Low HemoglobinTM. Blood loss volume was calculated as follows:<br>Blood loss volume (ml)=Hb concentration (g•l-1) x fluid volume (ml)/mean of preoperative and postoperative Hb concentration (g•l-1)<br>In two of the 24 patients, Hb concentration was lower than the detection limit (0.3g•l-1). Blood loss volume of 22 patients was estimated as 374±1104ml (mean±SD) (range: 28-1486ml). Blood loss volume did not have a significant correlation with the length of surgery or the weight of the resected prostate.